OEM Cleanup of Alerts (Warnings and Criticals) for All Targets

Make sure you want to do this before hand!

From your OEM Server:

alter session set current_schema=sysman;

SELECT ‘EXEC EM_SEVERITY.DELETE_CURRENT_SEVERITY(”’||TARGET_GUID||”’,”’||METRIC_GUID||”’,”’ ||KEY_VALUE||”’);’ MCS FROM MGMT_CURRENT_SEVERITY;

Then run the output generated.  This will cleanup and reset the value to Zero for all Warnings and Critical Alerts for All Targets being monitored.

Advertisements

About Thomas Baran

Work with the Best, Deliver nothing Less.
This entry was posted in Uncategorized and tagged . Bookmark the permalink.